CVEs of 2026.
Every CVE published in 2026 that we hold, ranked by exploit odds.
-
CVE-2025-14058
A potential missing authentication vulnerability was reported in some Lenovo Tablets that could allow an unauthorized user with physical access to modify Control Center settings if the device is locked when the "Allow Control Center access when locked" option is disabled.
-
CVE-2026-29797
No authentication is required when updating firmware or bootloader, making it easy for malicious files to be pushed to the device. Additionally, anyone with the same software can scan a network for N-Tron devices and push/pull firmware without authenticating by using SNMP/TFTP.
-
CVE-2026-123996
Hisense VIDAA Smart TV firmware V0000.01.00a.P0220 contains a missing authentication vulnerability in the UPnP/DLNA RenderingControl service on TCP port 38400 that allows a LAN-adjacent attacker to issue SetVolume, SetMute, and SelectPreset(FactoryDefaults) commands after a one-time DLNA pairing with no per-command authentication or session token. Attackers can send a continuous loop of unauthenticated commands to override the physical remote, change volume and mute, and reset all picture and audio calibration settings.
-
CVE-2026-17063
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, and FW1060.00 through FW1060.80 is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can access and disrupt host processor state, potentially affecting the managed system and all hosted partitions, resulting in an confidentiality, and availability impact.
-
CVE-2026-50245
Brickcom cameras allow unauthenticated access to live snapshot images via the /ONVIF endpoint and no authentication is required to retrieve still images from the camera feed.
-
CVE-2025-53697
Use of default credentials vulnerability in Johnson Controls iSTAR Ultra, Johnson Controls iSTAR Ultra SE, Johnson Controls iSTAR Ultra G2, Johnson Controls iSTAR Ultra G2 SE, and Johnson Controls iSTAR Edge G2 allows CAPEC‑560: Use of Default Credentials. This issue affects iSTAR Ultra: before 2.9.2.CU02; iSTAR Ultra SE: before 6.9.2.CU02; iSTAR Ultra G2: before 6.9.2.CU02; iSTAR Ultra G2 SE: before 6.9.2.CU02; iSTAR Edge G2: before 6.9.2.CU02.
-
CVE-2026-18848
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An attacker who can lure a logged-in ASMI administrator to visit a crafted web page can, under specific conditions, silently perform administrative actions on the FSP on behalf of that administrator, resulting in a confidentiality, integrity, and availability impact to the managed system.
-
CVE-2026-112692
This issue was addressed with additional entitlement checks. This issue is fixed in iOS 27.2 and iPadOS 27.2, tvOS 27.2, visionOS 27.2, watchOS 27.2. An app may be able to access sensitive user data.
-
CVE-2026-38056
A local privilege escalation vulnerability exists in the iDirect iQ200 VSAT terminal running firmware 23.0.1.0. The iQ200 is a rackmount satellite modem deployed across oil and gas, maritime, defense, and remote infrastructure as the primary, and often sole communications link for offshore rigs, vessels, and remote sites. Important context: the device ships from the factory with a pre-configured low-privilege local user account. This account is intended for field technicians who need shell access for maintenance and diagnostics but should not have full administrative control over the device. This built-in account provides the initial access required to exploit this vulnerability. No additional credentials need to be obtained or brute-forced.
-
CVE-2026-86989
An authorization issue was addressed with improved state management. This issue is fixed in iOS 26.7.2 and iPadOS 26.7.2, iOS 27.2 and iPadOS 27.2. An app may be able to fingerprint the user.
-
CVE-2026-112660
An authorization issue was addressed with improved state management. This issue is fixed in iOS 26.7.2 and iPadOS 26.7.2, iOS 27.2 and iPadOS 27.2, macOS Golden Gate 27.2, macOS Sequoia 15.8.2, macOS Tahoe 26.7.2, visionOS 27.2. An app may be able to bypass certain Privacy preferences.
-
CVE-2026-17429
IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, FW950.00 through FW950.H2, OP940.00 through OP940.a1 (Power9), and OP940.00 - OP940.81 (Power HMC) is affected by a vulnerability in the interface between the BMC/FSP and the host system. An attacker with service account or root access to the BMC/FSP can write arbitrary data to hardware control registers, allowing full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.
-
CVE-2026-127333
Vulnerability in the Oracle AutoVue product of Oracle Supply Chain (component: Security). The supported version that is affected is 21.1.0. Easily exploitable vulnerability allows unauthenticated attacker with access to the physical communication segment attached to the hardware where the Oracle AutoVue executes to compromise Oracle AutoVue. Successful attacks of this vulnerability can result in unauthorized read access to a subset of Oracle AutoVue accessible data. CVSS 3.1 Base Score 4.3 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N).
-
CVE-2026-127313
Vulnerability in the Oracle AutoVue product of Oracle Supply Chain (component: Security). The supported version that is affected is 21.1.0. Difficult to exploit vulnerability allows unauthenticated attacker with access to the physical communication segment attached to the hardware where the Oracle AutoVue executes to compromise Oracle AutoVue. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Oracle AutoVue accessible data as well as unauthorized access to critical data or complete access to all Oracle AutoVue accessible data. CVSS 3.1 Base Score 6.8 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N).
-
CVE-2026-127320
Vulnerability in the Oracle AutoVue product of Oracle Supply Chain (component: Security). The supported version that is affected is 21.1.0. Difficult to exploit vulnerability allows unauthenticated attacker with access to the physical communication segment attached to the hardware where the Oracle AutoVue executes to compromise Oracle AutoVue. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Oracle AutoVue accessible data as well as unauthorized access to critical data or complete access to all Oracle AutoVue accessible data. CVSS 3.1 Base Score 6.8 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N).
-
CVE-2026-58915
A physical occupant on an Android Automotive OS (AAOS) Multi-User Multi-Display (MUMD) passenger display can view sensitive Heads-Up Notification (HUN) content and execute actions for a secure passenger user (User N) without authenticating. This bypasses the PassengerKeyguard because the HUN system only checks the global keyguard state, which is tied to the driver's unlocked display, and the PassengerKeyguard implementation fails to suppress HUNs or intercept action PendingIntents. Consequently, private notification data is disclosed, and user-N actions are executed without credential verification.
-
CVE-2026-91386
Vulnerability in the JD Edwards EnterpriseOne Orchestrator product of Oracle JD Edwards (component: E1 IOT Orchestrator Security). Supported versions that are affected are 9.2.0.0-9.2.26.5. Difficult to exploit vulnerability allows unauthenticated attacker with access to the physical communication segment attached to the hardware where the JD Edwards EnterpriseOne Orchestrator executes to compromise JD Edwards EnterpriseOne Orchestrator. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all JD Edwards EnterpriseOne Orchestrator accessible data as well as unauthorized access to critical data or complete access to all JD Edwards EnterpriseOne Orchestrator accessible data. CVSS 3.1 Base Score 6.8 (Confidentiality and Integrity impacts). CVSS Vector: (CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N).
-
CVE-2026-21635
An Improper Access Control could allow a malicious actor in Wi-Fi range to the EV Station Lite (v1.5.2 and earlier) to use WiFi AutoLink feature on a device that was only adopted via Ethernet.
-
CVE-2026-34484
Nokia 1830 Global Express GX is vulnerable to a local privilege escalation vulnerability which exists in the administrative shell interface. An authenticated local attacker with restricted shell access can exploit this vulnerability to bypass local security restrictions and gain root access on the device.
-
CVE-2026-86955
An authorization issue was addressed with improved state management. This issue is fixed in iOS 27 and iPadOS 27. An app may be able to access sensitive user data.
-
CVE-2026-86921
A permissions issue was addressed with improved validation. This issue is fixed in iOS 26.7 and iPadOS 26.7, iOS 27 and iPadOS 27, macOS Golden Gate 27, visionOS 27. A local attacker may be able to overwrite restricted files.
-
CVE-2026-21159
Improper authorization in Samsung Pass prior to version 5.2.12.7 allows physical attackers to access sensitive information.
-
CVE-2026-84508
This issue was addressed with improved validation of the caller's access. This issue is fixed in iOS 27 and iPadOS 27, macOS Golden Gate 27, macOS Tahoe 26.7, visionOS 27. An app may be able to access protected user data.
-
CVE-2026-122124
On Yealink UVC40 E2 devices before 319.410.0.71, an attacker with short-term physical access can steal Wi‑Fi credentials via the USB interface. Sensitive data within the firmware configuration can be abused to gain root privileges on the device. Within Wi‑Fi coverage, the attacker may perform audio and video eavesdropping with no LED alert from the device.
-
CVE-2026-29123
A SUID root-owned binary in /home/xd/terminal/XDTerminal in International Data Casting (IDC) SFX2100 on Linux allows a local actor to potentially preform local privilege escalation depending on conditions of the system via execution of the affected SUID binary. This can be via PATH hijacking, symlink abuse or shared object hijacking.
-
CVE-2026-8864
The HP Fan Control App might allow local escalation of privileges. An updated version of HP Fan Control App has been released to mitigate this potential vulnerability.
-
CVE-2026-95652
Execution with unnecessary privileges vulnerability in TÜBİTAK BİLGEM Software Technologies Research Institute pardus-usb-formatter allows Privilege Abuse. This issue affects pardus-usb-formatter: from 0.7.0 before 0.7.2.
-
CVE-2026-84582
A privacy issue was addressed with improved access restrictions. This issue is fixed in iOS 27 and iPadOS 27, macOS Golden Gate 27, tvOS 27, visionOS 27, watchOS 27. An app may be able to access sensitive user data.
-
CVE-2026-20979
Improper privilege management in Settings prior to SMR Feb-2026 Release 1 allows local attackers to launch arbitrary activity with Settings privilege.
-
CVE-2026-84493
An authentication issue was addressed with improved state management. This issue is fixed in iOS 26.7.2 and iPadOS 26.7.2, iOS 27.2 and iPadOS 27.2. A malicious app may be able to access Bluetooth without user consent.
-
CVE-2026-97361
There exists an improper privilege management vulnerability that could cause privilege escalation at the SpaceCom and Space Battery pack SP with WiFi.
-
CVE-2026-49192
The summary service endpoint suffers from an IDOR vulnerability where it fails to verify user ownership of hardware serial numbers, exposing device data to scraping.
-
CVE-2026-29124
Multiple SUID root-owned binaries are found in /home/monitor/terminal, /home/monitor/kore-terminal, /home/monitor/IDE-DPack/terminal-dpack, and /home/monitor/IDE-DPack/terminal-dpack2 in International Data Casting (IDC) SFX2100 Satellite Receiver, which may lead to local privlidge escalation from the `monitor` user to root
-
CVE-2026-28645
In onStrongAuthRequiredChanged of UsbService.java, there is a possible unauthenticated enabling of USB data due to a logic error in the code. This could lead to physical escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.
-
CVE-2026-22694
AliasVault is a privacy-first password manager with built-in email aliasing. AliasVault Android versions 0.24.0 through 0.25.2 contained an issue in how passkey requests from Android apps were validated. Under certain local conditions, a malicious app could attempt to obtain a passkey response for a site it was not authorized to access. The issue involved incomplete validation of calling app identity, origin, and RP ID in the Android credential provider. This issue was fixed in AliasVault Android 0.25.3.
-
CVE-2026-109812
A missing authorization vulnerability exists in the internal API `/api/v1/secrets/` of some of Moxa's industrial computing products. A low-privileged authenticated attacker with adjacent network access could exploit this vulnerability to access sensitive information, potentially resulting in the disclosure of confidential data, including cryptographic key material.
-
CVE-2026-96577
A flaw was found in oc-mirror. During mirroring operations, the embedded local cache registry binds to all network interfaces without authentication or encryption instead of restricting access to the local system. An unauthenticated attacker on an adjacent network can connect to the exposed service to push tampered container images, delete cached images, or access mirrored content.
-
CVE-2025-57175
Siklu EtherHaul 8010 siklu-uimage-nxp-enc-10_6_2-18707-ea552dc00b devices have a static root password.
-
CVE-2026-24432
Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) lack cross-site request forgery (CSRF) protections on administrative endpoints, including those used to change administrator account credentials. As a result, an attacker can craft malicious requests that, when triggered by an authenticated user’s browser, modify administrative passwords and other configuration settings.
-
CVE-2026-119755
Tasmota through 16.0.0, fixed in commit 1cb7ebc, contains a cross-site request forgery vulnerability that allows unauthenticated attackers to bypass Referer-based CSRF protection in HttpCheckPriviledgedAccess() by crafting a Referer header where the device hostname or IP appears as a substring immediately after http://.evil.com/. Attackers can lure an administrator on the device's network to a malicious page to issue arbitrary console commands and reconfigure Wi-Fi, MQTT, settings, or firmware on devices lacking a WebPassword.
-
CVE-2026-13599
Missing authentication for critical function vulnerability in ABB Ability Edgenius. This issue affects Ability Edgenius: through 3.2.3.0.
-
CVE-2026-29521
Hereta ETH-IMC408M firmware version 1.0.15 and prior contain a cross-site request forgery vulnerability that allows attackers to modify device configuration by exploiting missing CSRF protections in setup.cgi. Attackers can host malicious pages that submit forged requests using automatically-included HTTP Basic Authentication credentials to add RADIUS accounts, alter network settings, or trigger diagnostics.
-
CVE-2026-127318
Vulnerability in the Oracle AutoVue product of Oracle Supply Chain (component: Security). The supported version that is affected is 21.1.0.7. Difficult to exploit vulnerability allows unauthenticated attacker with access to the physical communication segment attached to the hardware where the Oracle AutoVue executes to compromise Oracle AutoVue. Successful attacks of this vulnerability can result in unauthorized read access to a subset of Oracle AutoVue accessible data. CVSS 3.1 Base Score 3.1 (Confidentiality impacts). CVSS Vector: (CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N).
-
CVE-2026-7328
Missing authorization in Caliptra Core Runtime Firmware (INVOKE_DPE_MLDSA87, CM_AES_GCM_DECRYPT_DMA, EXTERNAL_MAILBOX_CMD commands) in subsystem mode allows a privileged local attacker to cause a denial of service via mailbox commands containing unverified AXI addresses. The security impact beyond availability is integration-specific. This issue affects Core Runtime Firmware: 2.1.0.
-
CVE-2025-13455
A vulnerability was reported in ThinkPlus configuration software that could allow a local authenticated user to bypass ThinkPlus device authentication and enroll an untrusted fingerprint.
-
CVE-2026-111253
A flaw was found in dnf5daemon-server. Session methods on dynamically exported D-Bus session objects do not verify that the caller is the unique sender that created the session. A local attacker can modify another user's live package-management session and replace its resolved transaction plan. If the legitimate session party later authorizes execution, the root daemon may apply the attacker-chosen package operations.
-
CVE-2026-108503
ZTE Z80 Ultra has an interface permission validation vulnerability. The callable functions provided by the system lack sufficient access control. An attacker can leverage these functions to read relevant information.
-
CVE-2026-108502
ZTE Z80 Ultra contains an information disclosure vulnerability, through which third-party applications can read relevant information by hooking system APIs.
-
CVE-2026-28988
A permissions issue was addressed with additional restrictions. This issue is fixed in iOS 26.5 and iPadOS 26.5, macOS Tahoe 26.5, visionOS 26.5, watchOS 26.5. An app may be able to bypass certain Privacy preferences.
-
CVE-2026-20978
Improper authorization in KnoxGuardManager prior to SMR Feb-2026 Release 1 allows local attackers to bypass the persistence configuration of the application.
CVE records published in 2026 (ids starting CVE-2026-), sorted by how likely they are to be exploited.