CVEs of 2025.
Every CVE published in 2025 that we hold, ranked by exploit odds.
-
CVE-2025-5848
A vulnerability was found in Tenda AC15 15.03.05.19_multi and classified as critical. Affected by this issue is the function formSetPPTPUserList of the file /goform/setPptpUserList of the component HTTP POST Request Handler. The manipulation of the argument list leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-5847
A vulnerability has been found in Tenda AC9 15.03.02.13 and classified as critical. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg of the component HTTP POST Request Handler. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-5608
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formsetreboottimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-6143
A vulnerability, which was classified as critical, was found in TOTOLINK EX1200T 4.1.2cu.5232_B20210713. Affected is an unknown function of the file /boafrm/formNtp of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-6137
A vulnerability classified as critical has been found in TOTOLINK T10 4.1.8cu.5207. Affected is the function setWiFiScheduleCfg of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument desc leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-12241
A vulnerability was detected in TOTOLINK A3300R 17.0.0cu.557_B20221024. This impacts the function setLanguageCfg of the file /cgi-bin/cstecgi.cgi of the component POST Parameter Handler. The manipulation of the argument lang results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is now public and may be used.
-
CVE-2025-12225
A vulnerability has been found in Tenda AC6 15.03.06.50. This issue affects some unknown processing of the file /goform/WifiGuestSet of the component HTTP Request Handler. Such manipulation of the argument shareSpeed leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2024-51138
Vigor165/166 4.2.7 and earlier; Vigor2620/LTE200 3.9.8.9 and earlier; Vigor2860/2925 3.9.8 and earlier; Vigor2862/2926 3.9.9.5 and earlier; Vigor2133/2762/2832 3.9.9 and earlier; Vigor2135/2765/2766 4.4.5. and earlier; Vigor2865/2866/2927 4.4.5.3 and earlier; Vigor2962 4.3.2.8 and earlier; Vigor3912 4.3.6.1 and earlier; Vigor3910 4.4.3.1 and earlier a stack-based buffer overflow vulnerability has been identified in the URL parsing functionality of the TR069 STUN server. This flaw occurs due to insufficient bounds checking on the amount of URL parameters, allowing an attacker to exploit the overflow by sending a maliciously crafted request. Consequently, a remote attacker can execute arbitrary code with elevated privileges.
-
CVE-2025-6824
A vulnerability classified as critical has been found in TOTOLINK X15 up to 1.0.0-B20230714.1105. Affected is an unknown function of the file /boafrm/formParentControl of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-12258
A vulnerability was detected in TOTOLINK A3300R 17.0.0cu.557_B20221024. Impacted is the function setOpModeCfg of the file /cgi-bin/cstecgi.cg of the component POST Parameter Handler. The manipulation of the argument opmode results in stack-based buffer overflow. The attack may be performed from remote.
-
CVE-2025-12259
A flaw has been found in TOTOLINK A3300R 17.0.0cu.557_B20221024. The affected element is the function setScheduleCfg of the file /cgi-bin/cstecgi.cgi of the component POST Parameter Handler. This manipulation of the argument recHour causes stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used.
-
CVE-2025-66647
RIOT is an open-source microcontroller operating system, designed to match the requirements of Internet of Things (IoT) devices and other embedded devices. A vulnerability was discovered in the IPv6 fragmentation reassembly implementation of RIOT OS v2025.07. When copying the contents of the first fragment (offset=0) into the reassembly buffer, no size check is performed. It is possible to force the creation of a small reassembly buffer by first sending a shorter fragment (also with offset=0). Overflowing the reassembly buffer corrupts the state of other packet buffers which an attacker might be able to used to achieve further memory corruption (potentially resulting in remote code execution). To trigger the vulnerability, the `gnrc_ipv6_ext_frag` module must be included and the attacker must be able to send arbitrary IPv6 packets to the victim. Version 2025.10 fixes the issue.
-
CVE-2025-46060
Buffer Overflow vulnerability in TOTOLINK N600R v4.3.0cu.7866_B2022506 allows a remote attacker to execute arbitrary code via the UPLOAD_FILENAME component
-
CVE-2025-3803
A vulnerability was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644). It has been rated as critical. This issue affects the function cgiSysScheduleRebootSet of the file /bin/httpd. The manipulation of the argument rebootDate leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-7747
A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. This affects the function fromWizardHandle of the file /goform/WizardHandle of the component POST Request Handler. The manipulation of the argument PPW leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-7505
A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function frmL7ProtForm of the file /goform/L7Prot of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-7506
A vulnerability classified as critical was found in Tenda FH451 1.0.0.9. Affected by this vulnerability is the function fromNatlimit of the file /goform/Natlimit of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-12273
A weakness has been identified in Tenda CH22 1.0.0.1. Affected is the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFilter. Executing a manipulation of the argument page can lead to buffer overflow. The attack may be launched remotely. The exploit has been made available to the public and could be used for attacks.
-
CVE-2025-11305
A vulnerability has been found in UTT HiPER 840G up to 3.1.1-190328. Affected by this issue is the function strcpy of the file /goform/formTaskEdit. The manipulation of the argument txtMin2 leads to buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2025-7116
A vulnerability classified as critical has been found in UTT 进取 750W up to 3.2.2-191225. This affects an unknown part of the file /goform/Fast_wireless_conf. The manipulation of the argument ssid leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2025-7571
A vulnerability classified as critical has been found in UTT HiPER 840G up to 3.1.1-190328. This affects an unknown part of the file /goform/aspApBasicConfigUrcp. The manipulation of the argument Username leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2025-7118
A vulnerability, which was classified as critical, has been found in UTT HiPER 840G up to 3.1.1-190328. This issue affects some unknown processing of the file /goform/formPictureUrl. The manipulation of the argument importpictureurl leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2025-7117
A vulnerability classified as critical was found in UTT HiPER 840G up to 3.1.1-190328. This vulnerability affects unknown code of the file /goform/websWhiteList. The manipulation of the argument addHostFilter leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2025-6733
A vulnerability was found in UTT HiPER 840G up to 3.1.1-190328. It has been declared as critical. This vulnerability affects the function sub_416928 of the file /goform/formConfigDnsFilterGlobal of the component API. The manipulation of the argument GroupName leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2025-6734
A vulnerability was found in UTT HiPER 840G up to 3.1.1-190328. It has been rated as critical. This issue affects the function sub_484E40 of the file /goform/formP2PLimitConfig of the component API. The manipulation of the argument except leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2025-6732
A vulnerability was found in UTT HiPER 840G up to 3.1.1-190328. It has been classified as critical. This affects the function strcpy of the file /goform/setSysAdm of the component API. The manipulation of the argument passwd1 leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2025-6302
A vulnerability, which was classified as critical, was found in TOTOLINK EX1200T 4.1.2cu.5232_B20210713. Affected is the function setStaticDhcpConfig of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument Comment leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-7758
A vulnerability, which was classified as critical, has been found in TOTOLINK T6 up to 4.1.5cu.748_B20211015. Affected by this issue is the function setDiagnosisCfg of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument ip leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-6887
A vulnerability was found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this issue is some unknown functionality of the file /goform/SetSysTimeCfg. The manipulation of the argument time/timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-6825
A vulnerability classified as critical was found in TOTOLINK A702R up to 4.0.0-B20230721.1521. Affected by this vulnerability is an unknown functionality of the file /boafrm/formWlSiteSurvey of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-5736
A vulnerability was found in TOTOLINK X15 1.0.0-B20230714.1105. It has been classified as critical. Affected is an unknown function of the file /boafrm/formNtp of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-5734
A vulnerability has been found in TOTOLINK X15 1.0.0-B20230714.1105 and classified as critical. This vulnerability affects unknown code of the file /boafrm/formWlanRedirect of the component HTTP POST Request Handler. The manipulation of the argument redirect-url leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-5735
A vulnerability was found in TOTOLINK X15 1.0.0-B20230714.1105 and classified as critical. This issue affects some unknown processing of the file /boafrm/formSetLg of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-4007
A vulnerability classified as critical was found in Tenda W12 and i24 3.0.0.4(2887)/3.0.0.5(3644). Affected by this vulnerability is the function cgidhcpsCfgSet of the file /goform/modules of the component httpd. The manipulation of the argument json leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2024-43663
There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High – Given the prevalence of these buffer overflows, and the clear error message of the web server, an attacker is very likely to be able to find these vulnerabilities. Impact: Low – Usually, overflowing one of these buffers just causes a segmentation fault of the CGI binary, which causes the web server to return a 502 Bad Gateway error. However the webserver itself is not affected, and no DoS can be achieved. Abusing these buffer overflows in a meaningful way requires highly technical knowledge, especially since ASLR also seems to be enabled on the charging station. However, a skilled attacker might be able to use one of these buffer overflows to obtain remote code execution. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack has a small impact on the availability of the device (VC:N/VI:N/VA:L). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect this vulnerability to have a safety impact. The attack can be automated (AU:Y).
-
CVE-2025-6336
A vulnerability was found in TOTOLINK EX1200T 4.1.2cu.5232_B20210713. It has been classified as critical. Affected is an unknown function of the file /boafrm/formTmultiAP of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-9023
A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-7806
A vulnerability classified as critical was found in Tenda FH451 1.0.0.9. This vulnerability affects the function fromSafeClientFilter of the file /goform/SafeClientFilter. The manipulation of the argument Go/page leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-7807
A vulnerability, which was classified as critical, has been found in Tenda FH451 1.0.0.9. This issue affects the function fromSafeUrlFilter of the file /goform/SafeUrlFilter. The manipulation of the argument Go/page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-7805
A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. This affects the function fromPptpUserSetting of the file /goform/PPTPUserSetting. The manipulation of the argument delno leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-5793
A vulnerability, which was classified as critical, was found in TOTOLINK EX1200T 4.1.2cu.5232_B20210713. Affected is an unknown function of the file /boafrm/formPortFw of the component HTTP POST Request Handler. The manipulation of the argument service_type leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-9813
A vulnerability was identified in Tenda CH22 1.0.0.1. This issue affects the function formSetSambaConf of the file /goform/SetSambaConf. The manipulation of the argument samba_userNameSda leads to buffer overflow. It is possible to initiate the attack remotely. The exploit is publicly available and might be used.
-
CVE-2025-15010
A vulnerability has been found in Tenda WH450 1.0.0.18. This issue affects some unknown processing of the file /goform/SafeUrlFilter. The manipulation of the argument page leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been disclosed to the public and may be used.
-
CVE-2025-15007
A security vulnerability has been detected in Tenda WH450 1.0.0.18. Affected by this issue is some unknown functionality of the file /goform/L7Im of the component HTTP Request Handler. Such manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
-
CVE-2024-51139
Buffer Overflow vulnerability in Vigor2620/LTE200 3.9.8.9 and earlier and Vigor2860/2925 3.9.8 and earlier and Vigor2862/2926 3.9.9.5 and earlier and Vigor2133/2762/2832 3.9.9 and earlier and Vigor165/166 4.2.7 and earlier and Vigor2135/2765/2766 4.4.5.1 and earlier and Vigor2865/2866/2927 4.4.5.3 and earlier and Vigor2962/3910 4.3.2.8/4.4.3.1 and earlier and Vigor3912 4.3.6.1 and earlier allows a remote attacker to execute arbitrary code via the CGI parser's handling of the "Content-Length" header of HTTP POST requests.
-
CVE-2025-7913
A vulnerability, which was classified as critical, was found in TOTOLINK T6 4.1.5cu.748_B20211015. Affected is the function updateWifiInfo of the component MQTT Service. The manipulation of the argument serverIp leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-6129
A vulnerability classified as critical was found in TOTOLINK EX1200T 4.1.2cu.5232_B20210713. This vulnerability affects unknown code of the file /boafrm/formSaveConfig of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-6940
A vulnerability classified as critical was found in TOTOLINK A702R 4.0.0-B20230721.1521. Affected by this vulnerability is an unknown functionality of the file /boafrm/formParentControl of the component HTTP POST Request Handler. The manipulation of the argument submit-url leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-7596
A vulnerability was found in Tenda FH1205 2.0.0.7(775). It has been rated as critical. This issue affects the function formWifiExtraSet of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2025-7597
A vulnerability classified as critical has been found in Tenda AX1803 1.0.0.1. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE records published in 2025 (ids starting CVE-2025-), sorted by how likely they are to be exploited.