CVEs of 2024.
Every CVE published in 2024 that we hold, ranked by exploit odds.
-
CVE-2024-8573
A vulnerability, which was classified as critical, was found in TOTOLINK AC1200 T8 and AC1200 T10 4.1.5cu.861_B20230220/4.1.8cu.5207. This affects the function setParentalRules of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument desc/week/sTime/eTime leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. Other parameters might be affected as well. The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2024-27944
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow a privileged user to upload firmware files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution.
-
CVE-2024-25995
An unauthenticated remote attacker can modify configurations to perform a remote code execution, gain root rights or perform an DoS due to improper input validation.
-
CVE-2024-36783
TOTOLINK LR350 V9.3.5u.6369_B20220309 was discovered to contain a command injection via the host_time parameter in the NTPSyncWithHost function.
-
CVE-2023-6234
Buffer overflow in CPCA Color LUT Resource Download process of Office Multifunction Printers and Laser Printers(*) which may allow an attacker on the network segment to trigger the affected product being unresponsive or to execute arbitrary code.*: Satera LBP670C Series/Satera MF750C Series firmware v03.07 and earlier sold in Japan. Color imageCLASS LBP674C/Color imageCLASS X LBP1333C/Color imageCLASS MF750C Series/Color imageCLASS X MF1333C Series firmware v03.07 and earlier sold in US. i-SENSYS LBP673Cdw/C1333P/i-SENSYS MF750C Series/C1333i Series firmware v03.07 and earlier sold in Europe.
-
CVE-2023-6229
Buffer overflow in CPCA PDL Resource Download process of Office Multifunction Printers and Laser Printers(*) which may allow an attacker on the network segment to trigger the affected product being unresponsive or to execute arbitrary code.*: Satera LBP670C Series/Satera MF750C Series firmware v03.07 and earlier sold in Japan. Color imageCLASS LBP674C/Color imageCLASS X LBP1333C/Color imageCLASS MF750C Series/Color imageCLASS X MF1333C Series firmware v03.07 and earlier sold in US. i-SENSYS LBP673Cdw/C1333P/i-SENSYS MF750C Series/C1333i Series firmware v03.07 and earlier sold in Europe.
-
CVE-2023-6231
Buffer overflow in WSD probe request process of Office Multifunction Printers and Laser Printers(*) which may allow an attacker on the network segment to trigger the affected product being unresponsive or to execute arbitrary code.*: Satera LBP670C Series/Satera MF750C Series firmware v03.07 and earlier sold in Japan. Color imageCLASS LBP674C/Color imageCLASS X LBP1333C/Color imageCLASS MF750C Series/Color imageCLASS X MF1333C Series firmware v03.07 and earlier sold in US. i-SENSYS LBP673Cdw/C1333P/i-SENSYS MF750C Series/C1333i Series firmware v03.07 and earlier sold in Europe.
-
CVE-2023-6233
Buffer overflow in SLP attribute request process of Office Multifunction Printers and Laser Printers(*) which may allow an attacker on the network segment to trigger the affected product being unresponsive or to execute arbitrary code.*: Satera LBP670C Series/Satera MF750C Series firmware v03.07 and earlier sold in Japan. Color imageCLASS LBP674C/Color imageCLASS X LBP1333C/Color imageCLASS MF750C Series/Color imageCLASS X MF1333C Series firmware v03.07 and earlier sold in US. i-SENSYS LBP673Cdw/C1333P/i-SENSYS MF750C Series/C1333i Series firmware v03.07 and earlier sold in Europe.
-
CVE-2024-7014
EvilVideo vulnerability allows sending malicious apps disguised as videos in Telegram for Android application affecting versions 10.14.4 and older.
-
CVE-2024-31807
TOTOLINK EX200 V4.0.3c.7646_B20201211 was discovered to contain a remote code execution (RCE) vulnerability via the hostTime parameter in the NTPSyncWithHost function.
-
CVE-2023-49959
In Indo-Sol PROFINET-INspektor NT through 2.4.0, a command injection vulnerability in the gedtupdater service of the firmware allows remote attackers to execute arbitrary system commands with root privileges via a crafted filename parameter in POST requests to the /api/updater/ctrl/start_update endpoint.
-
CVE-2024-7583
A vulnerability, which was classified as critical, has been found in Tenda i22 1.0.0.3(4687). This issue affects the function formApPortalOneKeyAuth of the file /goform/apPortalOneKeyAuth. The manipulation of the argument data leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2024-7582
A vulnerability classified as critical was found in Tenda i22 1.0.0.3(4687). This vulnerability affects the function formApPortalAccessCodeAuth of the file /goform/apPortalAccessCodeAuth. The manipulation of the argument accessCode/data/acceInfo leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2024-20082
In Modem, there is a possible memory corruption due to a missing bounds check. This could lead to remote code execution with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: MOLY01182594; Issue ID: MSV-1529.
-
CVE-2024-11065
The D-Link DSL6740C modem has an OS Command Injection vulnerability, allowing remote attackers with administrator privileges to inject and execute arbitrary system commands through a specific functionality provided by SSH and Telnet.
-
CVE-2024-11063
The D-Link DSL6740C modem has an OS Command Injection vulnerability, allowing remote attackers with administrator privileges to inject and execute arbitrary system commands through a specific functionality provided by SSH and Telnet.
-
CVE-2024-11064
The D-Link DSL6740C modem has an OS Command Injection vulnerability, allowing remote attackers with administrator privileges to inject and execute arbitrary system commands through a specific functionality provided by SSH and Telnet.
-
CVE-2024-11062
The D-Link DSL6740C modem has an OS Command Injection vulnerability, allowing remote attackers with administrator privileges to inject and execute arbitrary system commands through a specific functionality provided by SSH and Telnet.
-
CVE-2024-6189
A vulnerability was found in Tenda A301 15.13.08.12. It has been classified as critical. Affected is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-269160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2024-27945
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The bulk import feature of the affected systems allow a privileged user to upload files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution.
-
CVE-2024-7462
A vulnerability classified as critical has been found in TOTOLINK N350RT 9.3.5u.6139_B20201216. This affects the function setWizardCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument ssid leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-273555. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2024-50359
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "scan_ap" API which are not properly sanitized before being concatenated to OS level commands.
-
CVE-2023-5347
An Improper Verification of Cryptographic Signature vulnerability in the update process of Korenix JetNet Series allows replacing the whole operating system including Trusted Executables. This issue affects JetNet devices older than firmware version 2024/01.
-
CVE-2024-34206
TOTOLINK outdoor CPE CP450 v4.1.0cu.747_B20191224 was discovered to contain a command injection vulnerability in the setWebWlanIdx function via the webWlanIdx parameter.
-
CVE-2024-6963
A vulnerability, which was classified as critical, has been found in Tenda O3 1.0.0.10. This issue affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-272117 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2024-8580
A vulnerability classified as critical was found in TOTOLINK AC1200 T8 4.1.5cu.861_B20230220. This vulnerability affects unknown code of the file /etc/shadow.sample. The manipulation leads to use of hard-coded password. The attack can be initiated remotely. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2024-7585
A vulnerability has been found in Tenda i22 1.0.0.3(4687) and classified as critical. Affected by this vulnerability is the function formApPortalWebAuth of the file /goform/apPortalAuth. The manipulation of the argument webUserName/webUserPassword leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2023-51586
Voltronic Power ViewPower Pro selectEventConfig SQL Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower Pro. Authentication is not required to exploit this vulnerability. The specific flaw exists within the selectEventConfig method. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to execute code in the context of LOCAL SERVICE. Was ZDI-CAN-22072.
-
CVE-2023-3939
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in ZkTeco-based OEM devices allows OS Command Injection. Since all the found command implementations are executed from the superuser, their impact is the maximum possible. This issue affects ZkTeco-based OEM devices (ZkTeco ProFace X, Smartec ST-FR043, Smartec ST-FR041ME and possibly others) with the ZAM170-NF-1.8.25-7354-Ver1.0.0 and possibly other.
-
CVE-2024-27804
The issue was addressed with improved memory handling. This issue is fixed in iOS 17.5 and iPadOS 17.5, macOS Sonoma 14.5, tvOS 17.5, visionOS 1.3, watchOS 10.5. An app may be able to cause unexpected system termination.
-
CVE-2024-28955
Affected devices create coredump files when crashed, storing them with world-readable permission. Any local user of the device can examine the coredump files, and research the memory contents. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References].
-
CVE-2022-32502
An issue was discovered on certain Nuki Home Solutions devices. There is a buffer overflow over the encrypted token parsing logic in the HTTP service that allows remote code execution. This affects Nuki Bridge v1 before 1.22.0 and v2 before 2.13.2.
-
CVE-2024-10662
A vulnerability was found in Tenda AC15 15.03.05.19 and classified as critical. This issue affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2024-10434
A vulnerability was found in Tenda AC1206 up to 20241027. It has been classified as critical. This affects the function ate_Tenda_mfg_check_usb/ate_Tenda_mfg_check_usb3 of the file /goform/ate. The manipulation of the argument arg leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2024-8533
A privilege escalation vulnerability exists in the Rockwell Automation affected products. The vulnerability occurs due to improper default file permissions allowing users to exfiltrate credentials and escalate privileges.
-
CVE-2024-45824
CVE-2024-45824 IMPACT A remote code vulnerability exists in the affected products. The vulnerability occurs when chained with Path Traversal, Command Injection, and XSS Vulnerabilities and allows for full unauthenticated remote code execution. The link in the mitigations section below contains patches to fix this issue.
-
CVE-2024-10698
A vulnerability was found in Tenda AC6 15.03.05.19 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2022-32508
An issue was discovered on certain Nuki Home Solutions devices. By sending a malformed HTTP verb, it is possible to force a reboot of the device. This affects Nuki Bridge v1 before 1.22.0 and v2 before 2.13.2.
-
CVE-2023-7227
SystemK NVR 504/508/516 versions 2.3.5SK.30084998 and prior are vulnerable to a command injection vulnerability in the dynamic domain name system (DDNS) settings that could allow an attacker to execute arbitrary commands with root privileges.
-
CVE-2024-50371
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "wlan_scan" operation.
-
CVE-2024-50372
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "backup_config_to_utility" operation.
-
CVE-2024-50373
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by remote unauthenticated users capable of interacting with the default "edgserver" service enabled on the access point and malicious commands are executed with root privileges. No authentication is enabled on the service and the source of the vulnerability resides in processing code associated to the "restore_config_from_utility" operation.
-
CVE-2024-7707
A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Affected by this issue is the function formSafeEmailFilter of the file /goform/SafeEmailFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2024-11650
A vulnerability was found in Tenda i9 1.0.0.8(3828) and classified as critical. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
-
CVE-2024-11067
The D-Link DSL6740C modem has a Path Traversal Vulnerability, allowing unauthenticated remote attackers to exploit this vulnerability to read arbitrary system files. Additionally, since the device's default password is a combination of the MAC address, attackers can obtain the MAC address through this vulnerability and attempt to log in to the device using the default password.
-
CVE-2024-8878
The password recovery mechanism for the forgotten password in Riello Netman 204 allows an attacker to reset the admin password and take over control of the device.This issue affects Netman 204: through 4.05.
-
CVE-2024-28135
A low privileged remote attacker can use a command injection vulnerability in the API which performs remote code execution as the user-app user due to improper input validation. The confidentiality is partly affected.
-
CVE-2024-11665
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in hardy-barth cph2_echarge_firmware allows OS Command Injection.This issue affects cph2_echarge_firmware: through 2.0.4.
-
CVE-2024-7584
A vulnerability, which was classified as critical, was found in Tenda i22 1.0.0.3(4687). Affected is the function formApPortalPhoneAuth of the file /goform/apPortalPhoneAuth. The manipulation of the argument data leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
-
CVE-2024-27943
A vulnerability has been identified in RUGGEDCOM CROSSBOW (All versions < V5.5). The affected systems allow a privileged user to upload generic files to the root installation directory of the system. By replacing specific files, an attacker could tamper specific files or even achieve remote code execution.
CVE records published in 2024 (ids starting CVE-2024-), sorted by how likely they are to be exploited.