CVE-2026-79417
What it is
Improper Access Control in ArgusMonitor.sys in Argotronic eGbR ArgusMonitor 7.4.02 and earlier allows local, low-privileged users to bypass device handle access restrictions via a TOCTOU condition in IRP_MJ_CREATE and send a crafted IOCTL 0x9C4024A8 request, causing denial-of-service.
At a glance
- Exploitability
- Can be exploited over the network with a low-privilege account. High risk of service disruption.
- Exploit odds
- 0.2% chance of exploitation in the next 30 days (EPSS).
- Fix
- No patch or advisory is linked yet. Look at mitigations or restrict exposure.
Timeline
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Details
- Published
- Last modified
- Exploit probability
- 0.2% · EPSS, next 30 days
- Weakness
- CWE-284 · Improper access control
- Record status
- Deferred
Attack profile CVSS 3.1 · 5.3
- Attack vector
- Network
- Complexity
- High
- Privileges needed
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- None
- Integrity
- None
- Availability
- High
Raw vector
CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:N/A:H