CVE-2026-17583
What it is
The affected Thermo Fisher Applied Biosystems Genetic Analyzers are vulnerable because .fsa/.hid output files can be edited. An attacker could tamper with these files, altering DNA data and resulting in inaccurate DNA test outcomes.
At a glance
- Exploitability
- Can be exploited locally on the machine without logging in. High risk of data tampering, service disruption.
- Exploit odds
- 0.1% chance of exploitation in the next 30 days (EPSS).
- Fix
- A patch, advisory or fixed version is referenced. Upgrade or apply it.
Timeline
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Why it ranks here
- Exploited in the wild: no, CISA does not list it.
- Exploit odds: 0.1% in the next 30 days (EPSS).
- Severity: 8.3 HIGH (CVSS).
- Fix: a patch or advisory is linked.
Details
- Published
- Last modified
- Exploit probability
- 0.1% · EPSS, next 30 days
- Weakness
- CWE-353
- Record status
- Analyzed
Affected
- Thermofisher Abi Prism 310 Data Collection Software ≤ 3.1
- Thermofisher Abi Prism 3100\/3100-avant Data Collection Software ≤ 2.0
- Thermofisher Applied Biosystems 3130 Series Data Collection Software ≤ 4.1
- Thermofisher Applied Biosystems 3500\/3500xl Series Data Collection Software < 4.0.3
- Thermofisher Applied Biosystems 3730\/3730xl Series Data Collection Software < 5.0.3
- Thermofisher Applied Biosystems Seqstudio Flex Series Instrument Software < 1.2.1
- Thermofisher Applied Biosystems Seqstudio Genetic Analyzer Data Collection Software < 1.2.6
- Thermofisher Genemapper id-x < 1.7.4
Attack profile CVSS 4.0 · 8.3
- Attack vector
- Local
- Complexity
- Low
- Attack requirements
- None
- Privileges needed
- None
- User interaction
- None
- Confidentiality
- None
- Integrity
- High
- Availability
- High
Raw vector
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Is it in your code?
Hand this to your coding agent. It searches your project for the affected products and checks versions. Nothing leaves your machine.
Read https://cve-list.com/agent/cve/CVE-2026-17583.md and follow it. Check whether this project is affected by CVE-2026-17583. Read only. Don't change anything and don't upload my code. Tell me yes, no or not sure, with the file as proof.
Fix and advisories
- https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/fsa_hid_bulletin.pdf
- https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-216-01