CVE-2026-121192
What it is
@fastify/proxy-addr determines which network hops are trusted proxies and backs Fastify's trustProxy setting, so that forwarded headers can be believed. In versions 3.0.0 through 5.1.2, when trustProxy is configured with a zoned IPv6 link-local address, the trust comparison checks only the address bits and ignores the zone identifier, so a host on another link of a multi-homed server that carries the same link-local address is trusted as well. Such an attacker can spoof the X-Forwarded-For, X-Forwarded-Host and X-Forwarded-Proto headers, making the client IP, host and protocol reported by Fastify attacker-chosen values and defeating IP allowlists, rate limiting and audit logging. Exploitation requires a multi-homed server whose trustProxy is a zoned link-local address and an attacker directly on one of its other links; the default configuration and global, private or loopback trust entries are not affected. The issue is fixed in @fastify/proxy-addr 5.1.3, and users should upgrade to 5.1.3 or later. As a workaround, avoid trusting a zoned link-local address on a multi-homed host and trust a global, private or loopback proxy address instead.
At a glance
- Exploitability
- Can be exploited from the same network segment without logging in. High risk of data exposure, data tampering.
- Exploit odds
- 0.3% chance of exploitation in the next 30 days (EPSS).
- Fix
- A patch, advisory or fixed version is referenced. Upgrade or apply it.
Timeline
- ReservedThe CVE id was reserved by its CNA
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Why it ranks here
- Exploited in the wild: no, CISA does not list it.
- Exploit odds: 0.3% in the next 30 days (EPSS).
- Severity: 6.8 MEDIUM (CVSS).
- Fix: a patch or advisory is linked.
Details
- Published
- Last modified
- Exploit probability
- 0.3% · EPSS, next 30 days
- Weakness
- CWE-290
- Record status
- Awaiting Analysis
Attack profile CVSS 3.1 · 6.8
- Attack vector
- Adjacent network
- Complexity
- High
- Privileges needed
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- None
Raw vector
CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
Is it in your code?
Hand this to your coding agent. It searches your project for the affected products and checks versions. Nothing leaves your machine.
Read https://cve-list.com/agent/cve/CVE-2026-121192.md and follow it. Check whether this project is affected by CVE-2026-121192. Read only. Don't change anything and don't upload my code. Tell me yes, no or not sure, with the file as proof.