CVE-2023-46285
What it is
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). The affected application contains an improper input validation vulnerability that could allow an attacker to bring the service into a Denial-of-Service state by sending a specifically crafted message to 4004/tcp. The corresponding service is auto-restarted after the crash is detected by a watchdog.
At a glance
- Exploitability
- Can be exploited over the network without logging in. High risk of service disruption.
- Exploit odds
- 0.9% chance of exploitation in the next 30 days (EPSS).
- Fix
- A patch, advisory or fixed version is referenced. Upgrade or apply it.
Timeline
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Why it ranks here
- Exploited in the wild: no, CISA does not list it.
- Exploit odds: 0.9% in the next 30 days (EPSS).
- Severity: 7.5 HIGH (CVSS).
- Fix: a patch or advisory is linked.
Details
- Published
- Last modified
- Exploit probability
- 0.9% · EPSS, next 30 days
- Weakness
- CWE-20 · Improper input validation
- Record status
- Modified
Affected
- Siemens Opcenter Quality
- Siemens Simatic Pcs Neo < 4.1
- Siemens Sinumerik Integrate Runmyhmi \/automotive
- Siemens Totally Integrated Automation Portal < 15
- Siemens Totally Integrated Automation Portal < 16
- Siemens Totally Integrated Automation Portal < 17
- Siemens Totally Integrated Automation Portal < 18
- Siemens Totally Integrated Automation Portal
Attack profile CVSS 3.1 · 7.5
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- None
- Integrity
- None
- Availability
- High
Raw vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Is it in your code?
Hand this to your coding agent. It searches your project for the affected products and checks versions. Nothing leaves your machine.
Read https://cve-list.com/agent/cve/CVE-2023-46285.md and follow it. Check whether this project is affected by CVE-2023-46285. Read only. Don't change anything and don't upload my code. Tell me yes, no or not sure, with the file as proof.
Fix and advisories
- https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-999588.pdf