CVE-2023-2071
What it is
Rockwell Automation FactoryTalk View Machine Edition on the PanelView Plus, improperly verifies user’s input, which allows unauthenticated attacker to achieve remote code executed via crafted malicious packets. The device has the functionality, through a CIP class, to execute exported functions from libraries. There is a routine that restricts it to execute specific functions from two dynamic link library files. By using a CIP class, an attacker can upload a self-made library to the device which allows the attacker to bypass the security check and execute any code written in the function.
At a glance
- Exploitability
- Can be exploited over the network without logging in. High risk of data exposure, data tampering, service disruption.
- Exploit odds
- 17.3% chance of exploitation in the next 30 days (EPSS). Higher than most.
- Fix
- A patch, advisory or fixed version is referenced. Upgrade or apply it.
Timeline
- ReservedThe CVE id was reserved by its CNA
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Why it ranks here
- Exploited in the wild: no, CISA does not list it.
- Exploit odds: 17.3% in the next 30 days (EPSS).
- Severity: 9.8 CRITICAL (CVSS).
- Fix: a patch or advisory is linked.
Details
- Published
- Last modified
- Exploit probability
- 17.3% · EPSS, next 30 days
- Weakness
- CWE-20 · Improper input validation
- Record status
- Modified
Affected
- Rockwellautomation Factorytalk View ≤ 13.0
Attack profile CVSS 3.1 · 9.8
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Raw vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Is it in your code?
Hand this to your coding agent. It searches your project for the affected products and checks versions. Nothing leaves your machine.
Read https://cve-list.com/agent/cve/CVE-2023-2071.md and follow it. Check whether this project is affected by CVE-2023-2071. Read only. Don't change anything and don't upload my code. Tell me yes, no or not sure, with the file as proof.
Fix and advisories
- https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140724
- https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140724