A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior)
At a glance
- Exploitability
- Can be exploited over the network with an admin-level account. High risk of data tampering, service disruption.
- Exploit odds
- 0.3% chance of exploitation in the next 30 days (EPSS).
- Fix
- A patch, advisory or fixed version is referenced. Upgrade or apply it.
Timeline
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Why it ranks here
- Exploited in the wild: no, CISA does not list it.
- Exploit odds: 0.3% in the next 30 days (EPSS).
- Severity: 5.9 MEDIUM (CVSS).
- Fix: a patch or advisory is linked.
Details
- Published
- Last modified
- Exploit probability
- 0.3% · EPSS, next 30 days
- Weakness
- CWE-345
- Record status
- Modified
Affected
- schneider-electric Opc Ua Module For m580 Firmware ≤ 1.10
- schneider-electric x80 Advanced Rtu Module Firmware
Attack profile CVSS 3.1 · 5.9
- Attack vector
- Network
- Complexity
- High
- Privileges needed
- High
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- None
- Integrity
- High
- Availability
- High
Raw vector
CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:N/I:H/A:H
Is it in your code?
Hand this to your coding agent. It searches your project for the affected products and checks versions. Nothing leaves your machine.
Read https://cve-list.com/agent/cve/CVE-2022-34763.md and follow it. Check whether this project is affected by CVE-2022-34763. Read only. Don't change anything and don't upload my code. Tell me yes, no or not sure, with the file as proof.
Fix and advisories
- https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf
- https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf
References
- https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf
- https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-193-01_OPC_UA_X80_Advanced_RTU_Modicon_Communication_Modules+_Security_Notification.pdf