CVE-2021-27382
What it is
A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13040)
At a glance
- Exploitability
- Can be exploited locally on the machine without logging in, but needs a user to act. High risk of data exposure, data tampering, service disruption.
- Exploit odds
- 2.3% chance of exploitation in the next 30 days (EPSS).
- Fix
- A patch, advisory or fixed version is referenced. Upgrade or apply it.
Timeline
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Why it ranks here
- Exploited in the wild: no, CISA does not list it.
- Exploit odds: 2.3% in the next 30 days (EPSS).
- Severity: 7.8 HIGH (CVSS).
- Fix: a patch or advisory is linked.
Details
- Published
- Last modified
- Exploit probability
- 2.3% · EPSS, next 30 days
- Weakness
- CWE-121
- Record status
- Modified
Affected
- Siemens Solid Edge se2020 ≤ se2020mp13
- Siemens Solid Edge se2021 < se2021mp14
Attack profile CVSS 3.1 · 7.8
- Attack vector
- Local
- Complexity
- Low
- Privileges needed
- None
- User interaction
- Required
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Raw vector
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Is it in your code?
Hand this to your coding agent. It searches your project for the affected products and checks versions. Nothing leaves your machine.
Read https://cve-list.com/agent/cve/CVE-2021-27382.md and follow it. Check whether this project is affected by CVE-2021-27382. Read only. Don't change anything and don't upload my code. Tell me yes, no or not sure, with the file as proof.
Fix and advisories
- https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf
- https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06
- https://www.zerodayinitiative.com/advisories/ZDI-21-612/
- https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf
- https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06
- https://www.zerodayinitiative.com/advisories/ZDI-21-612/