CVE-2021-25667
What it is
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.
At a glance
- Exploitability
- Can be exploited from the same network segment without logging in. High risk of data exposure, data tampering, service disruption.
- Exploit odds
- 0.9% chance of exploitation in the next 30 days (EPSS).
- Fix
- A patch, advisory or fixed version is referenced. Upgrade or apply it.
Timeline
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Why it ranks here
- Exploited in the wild: no, CISA does not list it.
- Exploit odds: 0.9% in the next 30 days (EPSS).
- Severity: 8.8 HIGH (CVSS).
- Fix: a patch or advisory is linked.
Details
- Published
- Last modified
- Exploit probability
- 0.9% · EPSS, next 30 days
- Weakness
- CWE-121
- Record status
- Modified
Affected
- Siemens Ruggedcom rm1224 Firmware < 6.4
- Siemens Scalance m-800 Firmware < 6.4
- Siemens Scalance s615 Firmware < 6.4
- Siemens Scalance x300wg Firmware < 4.1
- Siemens Scalance xm400 Firmware < 6.2
- Siemens Scalance xr500 Firmware < 6.2
- Siemens Scalance sc622-2c Firmware ≤ 2.0
- Siemens Scalance sc622-2c Firmware < 2.1.3
Attack profile CVSS 3.1 · 8.8
- Attack vector
- Adjacent network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Raw vector
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Is it in your code?
Hand this to your coding agent. It searches your project for the affected products and checks versions. Nothing leaves your machine.
Read https://cve-list.com/agent/cve/CVE-2021-25667.md and follow it. Check whether this project is affected by CVE-2021-25667. Read only. Don't change anything and don't upload my code. Tell me yes, no or not sure, with the file as proof.
Fix and advisories
- https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf
- https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03
- https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf
- https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03