CVE-2021-22706
What it is
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.
At a glance
- Exploitability
- Can be exploited over the network without logging in, but needs a user to act. Limited direct impact.
- Exploit odds
- 0.8% chance of exploitation in the next 30 days (EPSS).
- Fix
- A patch, advisory or fixed version is referenced. Upgrade or apply it.
Timeline
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Why it ranks here
- Exploited in the wild: no, CISA does not list it.
- Exploit odds: 0.8% in the next 30 days (EPSS).
- Severity: 6.1 MEDIUM (CVSS).
- Fix: a patch or advisory is linked.
Details
- Published
- Last modified
- Exploit probability
- 0.8% · EPSS, next 30 days
- Weakness
- CWE-79 · Cross-site scripting
- Record status
- Modified
Affected
- schneider-electric Evlink City evc1s22p4 Firmware < r8_v3.4.0.1
- schneider-electric Evlink City evc1s7p4 Firmware < r8_v3.4.0.1
- schneider-electric Evlink Parking evw2 Firmware < r8_v3.4.0.1
- schneider-electric Evlink Parking evf2 Firmware < r8_v3.4.0.1
- schneider-electric Evlink Parking ev.2 Firmware < r8_v3.4.0.1
- schneider-electric Evlink Smart Wallbox evb1a Firmware < r8_v3.4.0.1
Attack profile CVSS 3.1 · 6.1
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- Required
- Scope
- Changed
- Confidentiality
- Low
- Integrity
- Low
- Availability
- None
Raw vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Is it in your code?
Hand this to your coding agent. It searches your project for the affected products and checks versions. Nothing leaves your machine.
Read https://cve-list.com/agent/cve/CVE-2021-22706.md and follow it. Check whether this project is affected by CVE-2021-22706. Read only. Don't change anything and don't upload my code. Tell me yes, no or not sure, with the file as proof.
Fix and advisories
- http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-06
- http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-194-06