CVE-2019-6538
What it is
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.
At a glance
- Exploitability
- Can be exploited from the same network segment without logging in. High risk of data tampering, service disruption.
- Exploit odds
- 0.9% chance of exploitation in the next 30 days (EPSS).
- Fix
- A patch, advisory or fixed version is referenced. Upgrade or apply it.
Timeline
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Why it ranks here
- Exploited in the wild: no, CISA does not list it.
- Exploit odds: 0.9% in the next 30 days (EPSS).
- Severity: 9.3 CRITICAL (CVSS).
- Fix: a patch or advisory is linked.
Details
- Published
- Last modified
- Exploit probability
- 0.9% · EPSS, next 30 days
- Weakness
- CWE-284 · Improper access control
- Record status
- Modified
Affected
- Medtronic Mycarelink Monitor Firmware 24950
- Medtronic Mycarelink Monitor Firmware 24952
- Medtronic Carelink Monitor Firmware 2490c
- Medtronic Carelink 2090 Firmware
- Medtronic Amplia crt-d Firmware
- Medtronic Claria crt-d Firmware
- Medtronic Compia crt-d Firmware
- Medtronic Concerto crt-d Firmware
Attack profile CVSS 3.1 · 9.3
- Attack vector
- Adjacent network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
- Scope
- Changed
- Confidentiality
- None
- Integrity
- High
- Availability
- High
Raw vector
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:H
Is it in your code?
Hand this to your coding agent. It searches your project for the affected products and checks versions. Nothing leaves your machine.
Read https://cve-list.com/agent/cve/CVE-2019-6538.md and follow it. Check whether this project is affected by CVE-2019-6538. Read only. Don't change anything and don't upload my code. Tell me yes, no or not sure, with the file as proof.
Fix and advisories
- https://ics-cert.us-cert.gov/advisories/ICSMA-19-080-01
- https://ics-cert.us-cert.gov/advisories/ICSMA-19-080-01