CVE-2018-11464
What it is
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.
At a glance
- Exploitability
- Can be exploited over the network without logging in. Limited direct impact.
- Exploit odds
- 1.9% chance of exploitation in the next 30 days (EPSS).
- Fix
- A patch, advisory or fixed version is referenced. Upgrade or apply it.
Timeline
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Why it ranks here
- Exploited in the wild: no, CISA does not list it.
- Exploit odds: 1.9% in the next 30 days (EPSS).
- Severity: 3.7 LOW (CVSS).
- Fix: a patch or advisory is linked.
Details
- Published
- Last modified
- Exploit probability
- 1.9% · EPSS, next 30 days
- Weakness
- CWE-248
- Record status
- Modified
Affected
- Siemens Sinumerik 828d Firmware ≤ 4.7
- Siemens Sinumerik 840d Sl Firmware ≤ 4.7
- Siemens Sinumerik 840d Sl Firmware ≤ 4.8
Attack profile CVSS 3.0 · 3.7
- Attack vector
- Network
- Complexity
- High
- Privileges needed
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- None
- Integrity
- None
- Availability
- Low
Raw vector
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:L
Is it in your code?
Hand this to your coding agent. It searches your project for the affected products and checks versions. Nothing leaves your machine.
Read https://cve-list.com/agent/cve/CVE-2018-11464.md and follow it. Check whether this project is affected by CVE-2018-11464. Read only. Don't change anything and don't upload my code. Tell me yes, no or not sure, with the file as proof.
Fix and advisories
- https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf