CVE-2017-9658
What it is
Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can necessitate intervention by hospital staff to reset the device and reestablish a network connection to the Wi-Fi access point. During this state, the Philips IntelliVue MX40 Version B.06.18 can either connect to an alternative access point within signal range for association to a central monitoring station, or it can remain in local monitoring mode until the device is reset by hospital staff. CVSS v3 base score: 6.5, CVSS vector string: AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Philips has released software update, Version B.06.18, to fix the improper cleanup on thrown exception vulnerability, and implement mitigations to reduce the risk associated with the improper handling of exceptional conditions vulnerability. The software update implements messaging and alarming on the MX40 and at the central monitoring station, when the MX40 disconnects from the access point.
At a glance
- Exploitability
- Can be exploited from the same network segment without logging in. High risk of service disruption.
- Exploit odds
- 0.8% chance of exploitation in the next 30 days (EPSS).
- Fix
- A patch, advisory or fixed version is referenced. Upgrade or apply it.
Timeline
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Why it ranks here
- Exploited in the wild: no, CISA does not list it.
- Exploit odds: 0.8% in the next 30 days (EPSS).
- Severity: 6.5 MEDIUM (CVSS).
- Fix: a patch or advisory is linked.
Details
- Published
- Last modified
- Exploit probability
- 0.8% · EPSS, next 30 days
- Weakness
- CWE-755
- Record status
- Modified
Affected
- Philips Intellivue mx40 Firmware < b.06.18
Attack profile CVSS 3.0 · 6.5
- Attack vector
- Adjacent network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- None
- Integrity
- None
- Availability
- High
Raw vector
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Is it in your code?
Hand this to your coding agent. It searches your project for the affected products and checks versions. Nothing leaves your machine.
Read https://cve-list.com/agent/cve/CVE-2017-9658.md and follow it. Check whether this project is affected by CVE-2017-9658. Read only. Don't change anything and don't upload my code. Tell me yes, no or not sure, with the file as proof.
Fix and advisories
- https://www.usa.philips.com/healthcare/about/customer-support/product-security
- https://www.usa.philips.com/healthcare/about/customer-support/product-security
References
- http://www.securityfocus.com/bid/100813
- https://ics-cert.us-cert.gov/advisories/ICSMA-17-255-01
- https://www.usa.philips.com/healthcare/about/customer-support/product-security
- http://www.securityfocus.com/bid/100813
- https://ics-cert.us-cert.gov/advisories/ICSMA-17-255-01
- https://www.usa.philips.com/healthcare/about/customer-support/product-security