CVE-2017-10724
What it is
Recently it was discovered as a part of the research on IoT devices in the most recent firmware for Shekar Endoscope that an attacker connected to the device Wi-Fi SSID can exploit a memory corruption issue and execute remote code on the device. This device acts as an Endoscope camera that allows its users to use it in various industrial systems and settings, car garages, and also in some cases in the medical clinics to get access to areas that are difficult for a human being to reach. Any breach of this system can allow an attacker to get access to video feed and pictures viewed by that user and might allow them to get a foot hold in air gapped networks especially in case of nation critical infrastructure/industries. The firmware contains binary uvc_stream that is the UDP daemon which is responsible for handling all the UDP requests that the device receives. The client application sends a UDP request to change the Wi-Fi name which contains the following format: "SETCMD0001+0002+[2 byte length of wifipassword]+[Wifipassword]. This request is handled by "control_Dev_thread" function which at address "0x00409AE4" compares the incoming request and determines if the 10th byte is 02 and if it is then it redirects to 0x0040A7D8, which calls the function "setwifipassword". The function "setwifipassword" uses a memcpy function but uses the length of the payload obtained by using strlen function as the third parameter which is the number of bytes to copy and this allows an attacker to overflow the function and control the $PC value.
At a glance
- Exploitability
- Can be exploited over the network with a low-privilege account. High risk of data exposure, data tampering, service disruption.
- Exploit odds
- 2.5% chance of exploitation in the next 30 days (EPSS).
- Fix
- No patch or advisory is linked yet. Look at mitigations or restrict exposure.
Timeline
- ReservedThe CVE id was reserved by its CNA
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Why it ranks here
- Exploited in the wild: no, CISA does not list it.
- Exploit odds: 2.5% in the next 30 days (EPSS).
- Severity: 8.8 HIGH (CVSS).
- Fix: none linked yet, which raises it.
Details
- Published
- Last modified
- Exploit probability
- 2.5% · EPSS, next 30 days
- Weakness
- CWE-119 · Buffer errors
- Record status
- Modified
Affected
- Ishekar Endoscope Camera Firmware
Attack profile CVSS 3.0 · 8.8
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Raw vector
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Is it in your code?
Hand this to your coding agent. It searches your project for the affected products and checks versions. Nothing leaves your machine.
Read https://cve-list.com/agent/cve/CVE-2017-10724.md and follow it. Check whether this project is affected by CVE-2017-10724. Read only. Don't change anything and don't upload my code. Tell me yes, no or not sure, with the file as proof.
References
- http://packetstormsecurity.com/files/153241/Shekar-Endoscope-Weak-Default-Settings-Memory-Corruption.html
- https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Shekar_boriscope_sec_issues.pdf
- https://seclists.org/bugtraq/2019/Jun/8
- http://packetstormsecurity.com/files/153241/Shekar-Endoscope-Weak-Default-Settings-Memory-Corruption.html
- https://github.com/ethanhunnt/IoT_vulnerabilities/blob/master/Shekar_boriscope_sec_issues.pdf
- https://seclists.org/bugtraq/2019/Jun/8