A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.83; SIPROTEC 7UT686 : All versions < V 4.01; SIPROTEC 7SD686 : All versions < V 4.03; SIPROTEC 7SJ66 : All versions < V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.
At a glance
- Exploitability
- Can be exploited over the network without logging in. Limited direct impact.
- Exploit odds
- 2.7% chance of exploitation in the next 30 days (EPSS).
- Fix
- A patch, advisory or fixed version is referenced. Upgrade or apply it.
Timeline
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Why it ranks here
- Exploited in the wild: no, CISA does not list it.
- Exploit odds: 2.7% in the next 30 days (EPSS).
- Severity: 5.3 MEDIUM (CVSS).
- Fix: a patch or advisory is linked.
Details
- Published
- Last modified
- Exploit probability
- 2.7% · EPSS, next 30 days
- Weakness
- CWE-200 · Information exposure
- Record status
- Modified
Affected
- Siemens Siprotec Firmware
- Siemens Siprotec Firmware 4.26
Attack profile CVSS 3.0 · 5.3
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- Low
- Integrity
- None
- Availability
- None
Raw vector
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Is it in your code?
Hand this to your coding agent. It searches your project for the affected products and checks versions. Nothing leaves your machine.
Read https://cve-list.com/agent/cve/CVE-2016-4784.md and follow it. Check whether this project is affected by CVE-2016-4784. Read only. Don't change anything and don't upload my code. Tell me yes, no or not sure, with the file as proof.
Fix and advisories
- http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf
- http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf
References
- http://www.securityfocus.com/bid/90773
- http://www.securityfocus.com/bid/99471
- http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf
- https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02
- https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03
- https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf
- http://www.securityfocus.com/bid/90773
- http://www.securityfocus.com/bid/99471
- http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf
- https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02
- https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03
- https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf