CVE-2015-8561
What it is
The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918.
At a glance
- Exploitability
- Can be exploited over the network without logging in. Limited direct impact.
- Exploit odds
- 3.8% chance of exploitation in the next 30 days (EPSS).
- Fix
- A patch, advisory or fixed version is referenced. Upgrade or apply it.
Timeline
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Why it ranks here
- Exploited in the wild: no, CISA does not list it.
- Exploit odds: 3.8% in the next 30 days (EPSS).
- Severity: 6.8 MEDIUM (CVSS).
- Fix: a patch or advisory is linked.
Details
- Published
- Last modified
- Exploit probability
- 3.8% · EPSS, next 30 days
- Weakness
- CWE-119 · Buffer errors
- Record status
- Modified
Affected
- schneider-electric Proclima ≤ 6.1
Attack profile CVSS 2.0 · 6.8
- Attack vector
- Network
- Complexity
- Medium
- Authentication
- None
- Confidentiality
- Partial
- Integrity
- Partial
- Availability
- Partial
Raw vector
AV:N/AC:M/Au:N/C:P/I:P/A:P
Is it in your code?
Hand this to your coding agent. It searches your project for the affected products and checks versions. Nothing leaves your machine.
Read https://cve-list.com/agent/cve/CVE-2015-8561.md and follow it. Check whether this project is affected by CVE-2015-8561. Read only. Don't change anything and don't upload my code. Tell me yes, no or not sure, with the file as proof.
Fix and advisories
- http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01
- http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01
References
- http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01
- http://www.zerodayinitiative.com/advisories/ZDI-15-626
- http://www.zerodayinitiative.com/advisories/ZDI-15-627
- http://www.zerodayinitiative.com/advisories/ZDI-15-628
- http://www.zerodayinitiative.com/advisories/ZDI-15-629
- https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02
- http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-329-01
- http://www.zerodayinitiative.com/advisories/ZDI-15-626
- http://www.zerodayinitiative.com/advisories/ZDI-15-627
- http://www.zerodayinitiative.com/advisories/ZDI-15-628
- http://www.zerodayinitiative.com/advisories/ZDI-15-629
- https://ics-cert.us-cert.gov/advisories/ICSA-15-335-02