CVE-2015-8214
What it is
A vulnerability has been identified in SIMATIC NET CP 342-5 (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions < V3.0.44), SIMATIC NET CP 343-1 Lean (incl. SIPLUS variants) (All versions < V3.1.1), SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants) (All versions < V3.1.1), SIMATIC NET CP 443-1 Advanced (incl. SIPLUS variants) (All versions < V3.2.9), SIMATIC NET CP 443-1 Standard (incl. SIPLUS variants) (All versions < V3.2.9), SIMATIC NET CP 443-5 Basic (incl. SIPLUS variants) (All versions), SIMATIC NET CP 443-5 Extended (All versions), TIM 3V-IE / TIM 3V-IE Advanced (incl. SIPLUS NET variants) (All versions < V2.6.0), TIM 3V-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.1.0), TIM 4R-IE (incl. SIPLUS NET variants) (All versions < V2.6.0), TIM 4R-IE DNP3 (incl. SIPLUS NET variants) (All versions < V3.1.0). The implemented access protection level enforcement of the affected communication processors (CP) could possibly allow unauthenticated users to perform administrative operations on the CPs if network access (port 102/TCP) is available and the CPs' configuration was stored on their corresponding CPUs.
At a glance
- Exploitability
- Can be exploited over the network without logging in. High risk of data tampering, service disruption.
- Exploit odds
- 2.1% chance of exploitation in the next 30 days (EPSS).
- Fix
- A patch, advisory or fixed version is referenced. Upgrade or apply it.
Timeline
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Why it ranks here
- Exploited in the wild: no, CISA does not list it.
- Exploit odds: 2.1% in the next 30 days (EPSS).
- Severity: 9.7 HIGH (CVSS).
- Fix: a patch or advisory is linked.
Details
- Published
- Last modified
- Exploit probability
- 2.1% · EPSS, next 30 days
- Weakness
- CWE-264
- Record status
- Modified
Affected
- Siemens Simatic Cp 443-1 Firmware
- Siemens Simatic Tim 4r-ie Firmware
- Siemens Simatic Cp 343-1 Firmware
- Siemens Simatic Cp 343-1 Firmware ≤ 3.0
- Siemens Simatic Tim 3v-ie Firmware
Attack profile CVSS 2.0 · 9.7
- Attack vector
- Network
- Complexity
- Low
- Authentication
- None
- Confidentiality
- Partial
- Integrity
- Complete
- Availability
- Complete
Raw vector
AV:N/AC:L/Au:N/C:P/I:C/A:C
Is it in your code?
Hand this to your coding agent. It searches your project for the affected products and checks versions. Nothing leaves your machine.
Read https://cve-list.com/agent/cve/CVE-2015-8214.md and follow it. Check whether this project is affected by CVE-2015-8214. Read only. Don't change anything and don't upload my code. Tell me yes, no or not sure, with the file as proof.
Fix and advisories
- http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-763427.pdf
- http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-763427.pdf
References
- http://www.securityfocus.com/bid/78345
- http://www.securitytracker.com/id/1034279
- http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-763427.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-763427.pdf
- http://www.securityfocus.com/bid/78345
- http://www.securitytracker.com/id/1034279
- http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-763427.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-763427.pdf