CVE-2013-0662
What it is
Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.
At a glance
- Exploitability
- Can be exploited over the network without logging in. High risk of data exposure, data tampering, service disruption.
- Exploit odds
- 22.2% chance of exploitation in the next 30 days (EPSS). Higher than most.
- Fix
- A patch, advisory or fixed version is referenced. Upgrade or apply it.
Timeline
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Why it ranks here
- Exploited in the wild: no, CISA does not list it.
- Exploit odds: 22.2% in the next 30 days (EPSS).
- Severity: 9.3 HIGH (CVSS).
- Fix: a patch or advisory is linked.
Details
- Published
- Last modified
- Exploit probability
- 22.2% · EPSS, next 30 days
- Weakness
- CWE-787 · Out-of-bounds write
- Record status
- Modified
Affected
- schneider-electric Concept ≤ 2.6
- schneider-electric Modbus Serial Driver 1.10
- schneider-electric Modbus Serial Driver 2.2
- schneider-electric Modbus Serial Driver 3.2
- schneider-electric Modbuscommdtm Sl ≤ 2.1.2
- schneider-electric Opc Factory Server ≤ 3.5.0
- schneider-electric Opc Factory Server 3.34
- schneider-electric Opc Factory Server 3.35
Attack profile CVSS 2.0 · 9.3
- Attack vector
- Network
- Complexity
- Medium
- Authentication
- None
- Confidentiality
- Complete
- Integrity
- Complete
- Availability
- Complete
Raw vector
AV:N/AC:M/Au:N/C:C/I:C/A:C
Is it in your code?
Hand this to your coding agent. It searches your project for the affected products and checks versions. Nothing leaves your machine.
Read https://cve-list.com/agent/cve/CVE-2013-0662.md and follow it. Check whether this project is affected by CVE-2013-0662. Read only. Don't change anything and don't upload my code. Tell me yes, no or not sure, with the file as proof.
Fix and advisories
- http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01
- http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01
- http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01
- http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01
References
- http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01
- http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01
- http://www.securityfocus.com/bid/66500
- https://www.exploit-db.com/exploits/45219/
- https://www.exploit-db.com/exploits/45220/
- http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01
- http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01
- http://www.securityfocus.com/bid/66500
- https://www.exploit-db.com/exploits/45219/
- https://www.exploit-db.com/exploits/45220/