CVE-2008-4390
What it is
The Cisco Linksys WVC54GC wireless video camera before firmware 1.25 sends cleartext configuration data in response to a Setup Wizard remote-management command, which allows remote attackers to obtain sensitive information such as passwords by sniffing the network.
At a glance
- Exploitability
- Can be exploited over the network without logging in. High risk of data exposure.
- Exploit odds
- 3.3% chance of exploitation in the next 30 days (EPSS).
- Fix
- A patch, advisory or fixed version is referenced. Upgrade or apply it.
Timeline
- PublishedDisclosed publicly on CVE.org and NVD
- Last updatedMost recent change to the record
Why it ranks here
- Exploited in the wild: no, CISA does not list it.
- Exploit odds: 3.3% in the next 30 days (EPSS).
- Severity: 7.5 HIGH (CVSS).
- Fix: a patch or advisory is linked.
Details
- Published
- Last modified
- Exploit probability
- 3.3% · EPSS, next 30 days
- Weakness
- CWE-319 · Cleartext transmission
- Record status
- Modified
Affected
- Cisco Linksys wvc54gc Firmware < 1.25
Attack profile CVSS 3.1 · 7.5
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
- Scope
- Unchanged
- Confidentiality
- High
- Integrity
- None
- Availability
- None
Raw vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Is it in your code?
Hand this to your coding agent. It searches your project for the affected products and checks versions. Nothing leaves your machine.
Read https://cve-list.com/agent/cve/CVE-2008-4390.md and follow it. Check whether this project is affected by CVE-2008-4390. Read only. Don't change anything and don't upload my code. Tell me yes, no or not sure, with the file as proof.
Fix and advisories
References
- http://secunia.com/advisories/33032
- http://www.kb.cert.org/vuls/id/528993
- http://www.kb.cert.org/vuls/id/MAPG-7HJKSA
- http://www.linksys.com/servlet/Satellite?blobcol=urldata&blobheadername1=Content-Type&blobheadername2=Content-Disposition&blobheadervalue1=text%2Fplain&blobheadervalue2=inline%3B+filename%3DWVC54GC-V1.0_non-RoHS-v1.25_fw_ver.txt&blobkey=id&blobtable=MungoBlobs&blobwhere=1193776031728&ssbinary=true&lid=8104724130B17
- http://www.securityfocus.com/bid/32666
- http://secunia.com/advisories/33032
- http://www.kb.cert.org/vuls/id/528993
- http://www.kb.cert.org/vuls/id/MAPG-7HJKSA
- http://www.linksys.com/servlet/Satellite?blobcol=urldata&blobheadername1=Content-Type&blobheadername2=Content-Disposition&blobheadervalue1=text%2Fplain&blobheadervalue2=inline%3B+filename%3DWVC54GC-V1.0_non-RoHS-v1.25_fw_ver.txt&blobkey=id&blobtable=MungoBlobs&blobwhere=1193776031728&ssbinary=true&lid=8104724130B17
- http://www.securityfocus.com/bid/32666